Pro-care Turn

Bilateral Turning Air Mattress

  • Medium to High Risk
  • 30° of bilateral turning therapy
  • Lateral Turning
  • Acute Sector

“A Turning Point for Better Patient Care”

  • Suitable for patients in medium to high risk of pressure injuries
  • Up to 30° of bilateral turning therapy to assist patient repositioning and enhance pressure relief
  • 3-in-1 therapy available for individual healthcare plans with effortless patient repositioning
  • Designed for caregivers to save time and resources while maintaining quality care to patients
0 °

Enhancing Pressure Relief by 30° of Bilateral Turning

Bilateral turning can significantly reduce interface pressure on patient´s body whilst increase capillary circulation. *1*2

30 degrees of turning not only complies with clinical guidelines but also provides optimal comfort.*3

Effective Pressure Relief by Bilateral Turning

The pressure mapping showcases a proven pressure relief off patient´s body by 30° of bilateral turning.

Effortless, 3-in-1 Therapy Solutions

Turning, Alternating and Continuous Low Pressure modes to tailor to individual pressure care plans

Improving Circulation & Skin Reperfusion

The unique setting for lateral turning therapy with alternating helps on skin reperfusion by the moderate pressure from each inflation cycle which improves body circulation and skin integrity

Patient Protection Level Up

The side bolsters reduce the risk of entrapment and accidental falling out of bed, also support patient´s arms while in turning therapy.

Heel Relief Function

Single air-cell deflation floats the vulnerable heels with zero pressure

  • 4-way Stretch Cover

    4-way Stretch Cover

    • Low friction and shear
    • Vapour permeable
    • High-flame retardant
    • Water resistant
  • Seat Inflation

    Seat Inflation

    Offering extra support in sacral area when in during sitting position

  • Cable Management

    Cable Management

    Cable management for a safety operational environment

  • Transport Mode

    Transport Mode

    Mattress remain to be a static surface for more than 6 hours during power failure and 8 hours for patient transfer

  • CPR Knob

    CPR Knob

    • CPR deflation time <15 sec.
    • Shorten deflation time of mattress to seek an efficient emergency care
  • Visual & audible alarm

    Visual & audible alarm

    • Power failure alarm
    • Low pressure alarm
    • Tech. Support alarm
  • Pause Function

    Pause Function

    In any scenario possible, it allows caregiver to temporarily stop the pump operation for 10 minutes

4-way Stretch Cover

4-way Stretch Cover

  • Low friction and shear
  • Vapour permeable
  • High-flame retardant
  • Water resistant
Seat Inflation

Seat Inflation

Offering extra support in sacral area when in during sitting position

Cable Management

Cable Management

Cable management for a safety operational environment

Transport Mode

Transport Mode

Mattress remain to be a static surface for more than 6 hours during power failure and 8 hours for patient transfer

CPR Knob

CPR Knob

  • CPR deflation time <15 sec.
  • Shorten deflation time of mattress to seek an efficient emergency care
Visual & audible alarm

Visual & audible alarm

  • Power failure alarm
  • Low pressure alarm
  • Tech. Support alarm
Pause Function

Pause Function

In any scenario possible, it allows caregiver to temporarily stop the pump operation for 10 minutes

References:
*1 Peterson MJ et al., Effects of turning on skin-bed interface pressures in healthy adults. Journal of advanced nursing. 2010
*2 Peterson MJ et al., Patient repositioning and pressure ulcer risk—Monitoring interface pressures of at-risk patients, JRRD 2013
*3 Prevention and Treatment of Pressure Ulcer: Clinical Practice Guideline (NPUAP/EPUAP/PPPIA 2014)

Video

APEX Pro-care Turn

Specifications

Model Pro-care Turn (5’’ Replacement)
Pump Dimensions  34.1 x 16.5 x 26.0 cm
Weight   4.5 kg / 9.9 lbs
Case Material  Flame Retardent ABS
Supply Voltage AC 230V, 50Hz
Operating Cycle Time 10, 15, 20, 25 min.
Dwell Time 10, 20, 30, 60 min.
Mattress Dimensions  200 x 90 x 13 cm, side bolster 25 cm
Cell Height 13 cm cells with two turning cells underneath from 4th to 12th air cells

Weight 11.4 Kg / 25 lbs
Cover Material 4-way stretch PU / Polyester cover with welded seams
Cell Material TPU
Maximum Patient Weight 180 kg / 397 lbs
Flame Retardant Standards EN 597-1 & EN 597-2
CPR Knob 1 Piece
Global - English

Cookies

We use cookies to optimize this website and continuously update it according to your needs.Please click on "Cookies" for detailed information on the use of cookies on this website. If you click "Yes, I agree", cookies will be activated. If you do not want cookies to be activated, you can opt out here. The settings can be changed at any time under "Cookies".

Yes, I agree.