“Simplicity Redefined”
- Suitable for patients in high to very high risk of pressure injuries
- Auto-sensing technology with intuitive one touch set up
- Multi-zone air pressure for greater pressure redistribution and optimal comfort
- Designed for improving work efficiency while performing the best pressure care to patients

One Touch Set Up
Prevention of pressure injury should be nothing but easy
- Initiating default programme after plugging-in
- Customised therapy mode or parameters by one touch
Intuitive Auto-Sensing Technology
- Auto-recognition
Automatically initiate corresponding pressure setting to different mattress - Auto-adjustment
Providing an optimal pressure in accordance with the patient’s weight distribution

Multi-zone Air Pressure for Optimal Comfort

The mattress fits various patient contours with stability and comfort in different zones for a better immersion and envelopment
Heel Relief Function
Single air-cell deflation can float the heels with zero pressure
Activating heel protection with the one-handed control knob


80% of Time Saving
Air Cells with quick release detachable base can be easily removed from mattress during decontamination


Extra Protection on the Sacrum
- Auto Seat Inflation
Initiates when the head section has been raised by ≥30 degrees to prevent bottoming out - Cell-in-Cell Air Cells (sacrum area)
Providing excellent support for patient in sitting-up position
-
Cable Management
Reducing tripping hazards for a safer healthcare environment
-
Transport Mode / Built-in Battery (Optional)
Non-stop dynamic pressure relief for more than 6 hours during power failure or transport (24 hours for transport mode without battery)
-
4-way Stretch Cover
- Low friction and shear
- Vapour permeable
- High-flame retardant
- Water resistant
-
CPR Knob
- CPR deflation time <15 sec.
- Shorten deflation time of mattress to seek an efficient emergency care
Specifications
Model | Pro-care Optima (8’’ Replacement ) | |
---|---|---|
Pump | Dimensions | 34.1 x 16.5 x 26.0cm |
Weight | Pump 5 kg (4.5 kg w/o battery) ; Mattress 9.2 kg | |
Case Material | Flame Retardent ABS | |
Supply Voltage | AC 220 - 240V, 50 Hz, 0.6A (w/ battery) AC 220 - 240V, 50 Hz, 0.34A (w/o battery) |
|
Cycle Time | 10/15/20/25 mins | |
Mattress | Mattress type | 8” Replacement |
Dimensions | 200 x 80 / 85 / 90 x 20 cm | |
Alternating | 1 - in - 2 | |
Cell Height | 21 x 8” Height | |
Cover Material | 4-way stretch PU / Polyester | |
Nylon PU quilted cover (Optional) | ||
Cell Material | TPU | |
Maximum Patient | 250 kg | |
Flame Retardant | EN 597-1 & EN 597-2 | |
CPR Knob | 1 Piece |
Download
-
2 MB2020-10-21
-
15 MB2019-05-20