“A Turning Point for Better Patient Care”
- Suitable for patients in medium to high risk of pressure injuries
- Up to 30° of bilateral turning therapy to assist patient repositioning and enhance pressure relief
- 3-in-1 therapy available for individual healthcare plans with effortless patient repositioning
- Designed for caregivers to save time and resources while maintaining quality care to patients

Enhancing Pressure Relief by 30° of Bilateral Turning
Bilateral turning can significantly reduce interface pressure on patient´s body whilst increase capillary circulation. *1*2
30 degrees of turning not only complies with clinical guidelines but also provides optimal comfort.*3

Effective Pressure Relief by Bilateral Turning
The pressure mapping showcases a proven pressure relief off patient´s body by 30° of bilateral turning.
Effortless, 3-in-1 Therapy Solutions
Turning, Alternating and Continuous Low Pressure modes to tailor to individual pressure care plans






Improving Circulation & Skin Reperfusion
The unique setting for lateral turning therapy with alternating helps on skin reperfusion by the moderate pressure from each inflation cycle which improves body circulation and skin integrity
Patient Protection Level Up
The side bolsters reduce the risk of entrapment and accidental falling out of bed, also support patient´s arms while in turning therapy.
Heel Relief Function
Single air-cell deflation floats the vulnerable heels with zero pressure
-
4-way Stretch Cover
- Low friction and shear
- Vapour permeable
- High-flame retardant
- Water resistant
-
Seat Inflation
Offering extra support in sacral area when in during sitting position
-
Cable Management
Cable management for a safety operational environment
-
Visual and Audible Alarm
- Low Pressure
- Power Failure
- Tech Support
-
Transport Mode
Mattress remain to be a static surface for more than 6 hours during power failure and 8 hours for patient transfer
-
CPR Knob
- CPR deflation time <15 sec.
- Shorten deflation time of mattress to seek an efficient emergency care.
-
Pause Function
In any scenario possible, it allows caregiver to temporarily stop the pump operation for 10 minutes
*2 Peterson MJ et al., Patient repositioning and pressure ulcer risk—Monitoring interface pressures of at-risk patients, JRRD 2013
*3 Prevention and Treatment of Pressure Ulcer: Clinical Practice Guideline (NPUAP/EPUAP/PPPIA 2014)
Specifications
Model | Pro-care Turn (5’’ Replacement) | |
---|---|---|
Pump | Dimensions | 34.1 x 16.5 x 26.0 cm |
Weight | 4.5 kg / 9.9 lbs | |
Case Material | Flame Retardent ABS | |
Supply Voltage | AC 230V, 50Hz | |
Operating Cycle Time | 10, 15, 20, 25 min. | |
Dwell Time | 10, 20, 30, 60 min. | |
Mattress | Dimensions | 200 x 90 x 13 cm, side bolster 25 cm |
Cell Height | 13 cm cells with two turning cells underneath from the 4th to 12th air cells | |
Weight | 11.4 kg / 25 lbs | |
Cover Material | 4-way stretch PU / Polyester cover with welded seams | |
Cell Material | TPU | |
Maximum Patient Weight | 180 kg / 397 lbs | |
CPR Knob | 1 Piece | |
Flame Retardant Standards | EN 597-1 & EN 597-2 |
Download
-
2 MB2020-10-21
-
15 MB2019-05-20
-
6 MB2020-10-19